Shear Beam Loadcell

WMCT15

  • Specially Designed For Hopper And Tank(5t~15t)

     Mounts directly to the floor or structural support.

    Self checking with provisions for themaI expansion and contraction.


  • PDF:WMCT15
  • INQUIRY

Weigh Module

Series WMCT15

Specially Designed For Hopper And Tank(5t~15t)

  

-Mounts directly to the floor or structural support.

-Self checking with provisions for themaI expansion and contraction.


SPECIFICATIONS                                                                                                                                   

TYPE

WMCT15

Rated   capacity (R.C.)

5,10,15t

Rated   output(R.O.)

3mV/V   ± 0.25%

Non-linearity

≤0.03% R.O.

Hysteresis

≤0.03% R.O.

Non-repeatability

≤0.03% R.O.

Creep   error

≤0.03% in 20min

Zero   balance

≤1% R.O.

Compensated   temperature range

-10   ~ 70

Operating   temperature range

-20   ~ 80

Temp.   effect on rated output

≤0.02% LOAD/10℃

Temp.effect   on zero balance

≤0.03% R.O./10℃

Terminal   input resistance

700   Ohms ± 10 Ohms

Terminal   output resistance

700   Ohms ± 7 Ohms

Insulation   resistance (Min.)

2000   MOhms at 50V DC

Excitation   voltage

10V(Recommended),15V(Max.)

Electrical   connection

Ø7mmx6m(22AWG x 4Core Shielded)

Protection   class

meets IP   67

Safe   overload

150%   R.C

Ultimate   overload

300%   R.C


image.png

image.png


* Specifications are subject to change without notice